UST100 Model devices are used to convert analog signals that are created in any environment to standart analog signals isolated from input.
These devices have one universal analog input and one analog output.
These devices are based with microcontrollers and can be configured easily by using SBA100 USB/UART Converter.
Input and output are isolated.
For the detailed information about device,[Device Catalog] ve [User Guide] links can be used. |
|
|
|
|


SENSOR TYPE |
STANDARD |
Temperature Range |
(° C) |
(° F ) |
Type-B Thermocouple |
IEC584-1 |
60, 1820 |
140, 3308 |
Type-E Thermocouple |
IEC584-1 |
-200, 840 |
-328, 1544 |
Type-J Thermocouple |
IEC584-1 |
-200, 1120 |
-328, 1562 |
Type-K Thermocouple |
IEC584-1 |
-200, 1360 |
-328, 2480 |
Type-L Thermocouple |
DIN43710 |
-200, 900 |
-328, 1652 |
Type-N Thermocouple |
IEC584-1 |
-200, 1300 |
-328, 2372 |
Type-R Thermocouple |
IEC584-1 |
-40, 1760 |
104, 3200 |
Type-S Thermocouple |
IEC584-1 |
-40, 1760 |
104, 3200 |
Type-T Thermocouple |
IEC584-1 |
-200, 400 |
-328, 752 |
Type-U Thermocouple |
DIN43710 |
-200, 600 |
-328, 1112 |
PT-100 |
IEC751 |
-200, 840 |
-328, 1544 |
|
| TECHNICAL SPECIFICATIONS |
| Supply Voltage |
100-240Vac/dc: +%10- %15 |
24Vac/dc: +%10- %20 |
| Power Consumption |
2W, 3VA |
| Analog Input (I1) |
Thermocouple :B,E,J,K,L,N,R,S,T,U |
| Resistance Thermometer: PT100 |
| Current: 0/4-20mA |
| Voltage: 0-50mV |
| Analog Input Impedance |
Thermocouple, mV:10MΩ |
| Current: 10 Ω |
| Analog Output(O1) |
Current: 0/4-20mA
(RL≤500Ω) |
Voltage: 0/2V-10V
(RL ≥ 1MΩ ) |
| Contact Lifetime |
Without load : 10.000.000 switching, With 250V 3A Resistive load: 100.000 switching |
| Memory |
100 yearl, 100.000 renewals |
| Accuracy |
+/- % 0.2 |
| Sampling Period |
400ms |
| Environment Temperature |
Operation: -10...+55° C |
Storage: -20...+65° C |
| Protection |
Trunk:IP20 |
| Dimensions |
Width: 25mm, Height: 91mm, Depth: 113mm |
| Weight |
134gr |
|
|
|