ENGLISH
 
 
UST100 SINGLE CHANNEL UNIVERSAL TRANSMITTER

UST100 Model devices are used to convert analog signals that are created in any environment to standart analog signals isolated from input.

These devices have one universal analog input and one analog output. These devices are based with microcontrollers and can be configured easily by using SBA100 USB/UART Converter. Input and output are isolated.

For the detailed information about device,[Device Catalog] ve [User Guide] links can be used.

 

UST100 Single Channel Transmitter
UST200
HMT420
CONNECTION DIAGRAM

UST100 Connection Diagram

PRODUCT CODE

UST100 CProduct Code

SENSOR TYPES

 

SENSOR TYPE
STANDARD
Temperature Range
(° C)
(° F )
Type-B Thermocouple
IEC584-1
60, 1820
140, 3308
Type-E Thermocouple
IEC584-1
-200, 840
-328, 1544
Type-J Thermocouple
IEC584-1
-200, 1120
-328, 1562
Type-K Thermocouple
IEC584-1
-200, 1360
-328, 2480
Type-L Thermocouple
DIN43710
-200, 900
-328, 1652
Type-N Thermocouple
IEC584-1
-200, 1300
-328, 2372
Type-R Thermocouple
IEC584-1
-40, 1760
104, 3200
Type-S Thermocouple
IEC584-1
-40, 1760
104, 3200
Type-T Thermocouple
IEC584-1
-200, 400
-328, 752
Type-U Thermocouple
DIN43710
-200, 600
-328, 1112
PT-100
IEC751
-200, 840
-328, 1544


TECHNICAL SPECIFICATIONS
Supply Voltage 100-240Vac/dc: +%10- %15 24Vac/dc: +%10- %20
Power Consumption 2W, 3VA
Analog Input (I1) Thermocouple :B,E,J,K,L,N,R,S,T,U
Resistance Thermometer: PT100
Current: 0/4-20mA
Voltage: 0-50mV
Analog Input Impedance Thermocouple, mV:10MΩ
Current: 10 Ω
Analog Output(O1) Current: 0/4-20mA (RL≤500Ω) Voltage: 0/2V-10V (RL ≥ 1MΩ )
Contact Lifetime Without load : 10.000.000 switching, With 250V 3A Resistive load: 100.000 switching
Memory 100 yearl, 100.000 renewals
Accuracy +/- % 0.2
Sampling Period 400ms
Environment Temperature Operation: -10...+55° C Storage: -20...+65° C
Protection Trunk:IP20
Dimensions Width: 25mm, Height: 91mm, Depth: 113mm
Weight 134gr
Copyright © 2005 ORDEL Ltd. Sti. All Rights Reserved