These types of thermocouples are produced with the aim of potability. They have
fixed length cables. They have a wide usage area. They are used immerting into
the glass or metal pots. They are produced in various dimentions and lengths.
|
|
|
Handleable, fixed length cabled, portable thermocouple. Diameter of 4,5,6,8mm
protecting tubes are used.
|
|
|
Handleable, fixed length cabled, portable thermocouple. 4,5,6,8mm protecting
tubes are used. In order to increase the response time and accuracy, diameter
decreases at the value of 50mm in top point.
|
|
|
These type of thermocouples are used to measure the temperature of staight
areas. They are hadleable, mobile and fixed length cabled thermocouples.
4,5,6,8mm protecting tubes are used. Thermocouple shouldn't be moved while
measurement operations. It is not preferred to use these thermocouples in non
straight areas. If top points are ordered angular, they are coded as OT09-B1.
|
|
|
is used in soft environments. (dough,sponge, rubber). It has a staight pin.
|
|
|
Used in flesh aired environments. Element wire is protected with a perforated
pipe. So that anvironment temperature is measured correctly.
|
|
|
Socketed type. Miniature or standard type socket is connected to
thermocouple's connecting point. Socket tips are the same as thermocouple's
element wire. S is used for Special and M is used for Miniature in Special
Conditions part while coding.
|
|
|
They are assebled onto copper plaque and measures the temperature over this
plaque. They are preferred to measure high temperatures.
|
|
|
These type of thermocouples have fixed cable and mouting bush. Mouting bush is
½" as standard. The temperature of the mouting bush should not be over 100°C. If
mounting bush is ordered as switch or cable output pipe or springed, they are
coded as OT12-A.
|
|
|
It has a fixed cable and moveable mouting bush. Mouting bush is ½" as
standard.
|
|
|
These types of thermocouples have fixed cable and pipe clip. Generally, they are
used to measure the temperature of pipe surfaces. They are connected to pipe
with the help of pipe clip.
|
|
|
These types of thermocouples are preferred in the measurement of exhaust
temperature. They are connected to process with the help of regulateable
mounting bush. In order to increase the accuracy , the diameter of the top point
is decreased.
|
|
|
These types of thermocouples are preferred in the measurement of exhaust
temperature. Difference from OT16 is cable output which is 90°. They are
connected to process with the help of regulateable mounting bush. In order to
increase the accuracy , the diameter of the top point is decreased.
|
|
|
These types of thermocouples are preferred in the measurement of exhaust
temperature. Difference from OT16 and OT16-A is the top point. It is produced as
stepless. Other features are same as OT16.
|
|
|