OT01
|
|
|
is straght type and do not have mounting bush. B type
head is used as standard. OR05 inset is used. |
|
|
OR02
|
|
|
has mouting bush. Standard mounting bush is½". It is
assembled just below the head. OR05 inset is used. |
|
|
|
OR03
|
|
|
has mouting bush. The distance between head and mounting bush is 120mm. Standard
mounting bush is½". OR05 inset is used. They are preferred in some processes
that requires a meaningful distance between head and mouting bush. |
|
|
OR04
|
|
|
has mouting bush. The distance between head and mounting bush is 145mm.
Standard mounting bush is½". OR05 inset is used. They are preferred in some
processes that requires a meaningful distance between head and mouting bush. If
it is ordered with steenless mouting bush and union, it is coded as OR04-A.
|
|
|
OR05 |
|
|
has inset. While ordering, inset length should be
determined.
|
|
OR06 |
|
|
has fixed cable and mounting bush. The temperature of the mounting bush
should not be above 100°C. Standard mounting bush is½". Cable length should be
determined while ordering.
|
|
OR07 |
|
|
is straght type resistance thermometer and has fixed
cable. A straight pipe is placed at top of cable. This pipe is producted in
various diameters at L1 length.If spring is ordered at cable output, RT is coded
as OR07-A.
|
|
OR08 |
|
|
is a bayonet type resistance thermometer with fixed cable. Top point of
resistance thermometer is fixed into the process with a spring mounting bush.
Standard mounting bush is M12x1,5, L length is 300mm and the diameter is 6mm. It
can be produced within various lengths. Cable length and cable type should be
determined while ordering. |
|
OR09 |
|
|
has fixed cable and portable. Standard types are produced at the diameter
of 4,5,6,8mm. It is important to notice while determining the length because of
handle that may be effected by temperature. |
|
OR09-A |
|
|
is fixed wired and portable type resistance thermometer. It is used to
measure the temperature of straight surfaces. It is used by pressing the
surface. If it is ordered with angle, it is coded with OR09-A1. |
|
OR09-B |
|
|
is a portable resistance thermometer that is used in soft
environments.(dough,sponge, rubber). |
|
OR09-C |
|
|
is a handleable, fixed cabled portable type resistance thermometer. It is
used in non corrosive environments. As it can be seed from image, Pt-100 element
is protected because of open areas. So that the environment temperature is
measured correctly. If it is ordered with holed protecting tube , it is coded as
OR09-C1. |
|
OR10 |
|
|
is a miniature type resistance thermometer which is used to measure air
temperature with high sensitivity. There is a perforated protector that protects
element. Mounting bush is M10x1,5'dur. It can be ordered with glass element
also. Glass has higher response time than ceramic element. But it is more
expensive than the others. If glass element is ordered, it should be coded with
"C" in special parts section. |